6 resultados para controlled variable

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents a multi-cell single-phase high power factor boost rectifier in interleave connection, operating in critical conduction mode, employing a soft-switching technique, and controlled by Field Programmable Gate Array (FPGA). The soft-switching technique is based on zero-current-switching (ZCS) cells, providing ZC (zero-current) turn-on and ZCZV (zero-current-zero-voltage) turn-off for the active switches, and ZV (zero-vohage) turn-on and ZC (zero-current) turn-off for the boost diodes. The disadvantages related to reverse recovery effects of boost diodes operated in continuous conduction mode (additional losses, and electromagnetic interference (EMI) problems) are minimized, due to the operation in critical conduction mode. In addition, due to the interleaving technique, the rectifier's features include the reduction in the input current ripple, the reduction in the output voltage ripple, the use of low stress devices, low volume for the EMI input filter, high input power factor (PF), and low total harmonic distortion (THD) in the input current, in compliance with the IEC61000-3-2 standards. The digital controller has been developed using a hardware description language (VHDL) and implemented using a XC2S200E-SpartanII-E/Xilinx FPGA device, performing a true critical conduction operation mode for all interleaved cells, and a closed-loop to provide the output voltage regulation, like as a preregulator rectifier. Experimental results are presented for a implemented prototype with two and with four interleaved cells, 400V nominal output voltage and 220V(rms) nominal input voltage, in order to verify the feasibility and performance of the proposed digital control through the use of a FPGA device.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel single-phase voltage source rectifier capable to achieve High-Power-Factor (HPF) for variable speed refrigeration system application, is proposed in this paper. The proposed system is composed by a single-phase high-power-factor boost rectifier, with two cells in interleave connection, operating in critical conduction mode, and employing a soft-switching technique, controlled by a Field Programmable Gate Array (FPGA), associated with a conventional three-phase IGBT bridge inverter (VSI - Voltage Source Inverter), controlled by a Digital Signal Processor (DSP). The soft-switching technique for the input stage is based on zero-current-switching (ZCS) cells. The rectifier's features include the reduction in the input current ripple, the reduction in the output voltage ripple, the use of low stress devices, low volume for the EMI input filter, high input power factor (PF), and low total harmonic distortion (THD) in the input current, in compliance with the EEC61000-3-2 standards. The digital controller for the output stage has been developed using a conventional voltage-frequency control (scalar V/f control), and a simplified stator oriented Vector control, in order to verify the feasibility and performance of the proposed digital controls for continuous temperature control applied at a refrigerator prototype.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Some children with juvenile idiopathic arthritis either do not respond, or are intolerant to, treatment with disease-modifying antirheumatic drugs, including anti-tumour necrosis factor (TNF) drugs. We aimed to assess the safety and efficacy of abatacept, a selective T-cell costimulation modulator, in children with juvenile idiopathic arthritis who had failed previous treatments.Methods We did a double-blind, randomised controlled withdrawal trial between February, 2004, and June, 2006. We enrolled 190 patients aged 6-17 years, from 45 centres, who had a history of active juvenile idiopathic arthritis; at least five active joints; and an inadequate response to, or intolerance to, at least one disease-modifying antirheumatic drug. All 190 patients were given 10 mg/kg of abatacept intravenously in the open-label period of 4 months. of the 170 patients who completed this lead-in course, 47 did not respond to the treatment according to predefined American College of Rheumatology (ACR) paediatric criteria and were excluded. of the patients who did respond to abatacept, arthritis, and 62 were randomly assigned to receive placebo at the same dose and timing. The primary endpoint was time to flare of arthritis. Flare was defined as worsening of 30% or more in at least three of six core variables, with at least 30% improvement in no more than one variable. We analysed all patients who were treated as per protocol. This trial is registered, number NCT00095173.Findings Flares of arthritis occurred in 33 of 62 (53%) patients who were given placebo and 12 of 60 (20%) abatacept patients during the double-blind treatment (p=0.0003). Median time to flare of arthritis was 6 months for patients given placebo (insufficient events to calculate IQR); insufficient events had occurred in the abatacept group for median time to flare to be assessed (p=0.0002). The risk of flare in patients who contined abatacept was less than a third of that for controls during that double-blind period (hazard ratio 0.31, 95% CI 0.16-0.95). During the double-blind period, the frequency of adverse events did not differ in the two treatment groups, Adverse events were recorded in 37 abatacept recipients (62%) and 34 (55%) placebo recipients (p=0.47); only two serious adverse events were reported, bouth in controls (p=0.50).Interpretation Selective modulation of T-cell costimulation with abatacept is a rational alternative treatment for children with juvenile idiopathic arthritis.Funding Bristol-Myers Squibb.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An analog circuit that implements a radial basis function network is presented. The proposed circuit allows the adjustment of all shape parameters of the radial functions, i.e., amplitude, center and width. The implemented network was applied to the linearization of a nonlinear circuit, a voltage controlled oscillator (VCO). This application can be classified as an open-loop control in which the network plays the role of the controller. Experimental results have proved the linearization capability of the proposed circuit. Its performance can be improved by using a network with more basis functions. Copyright 2007 ACM.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A model of energy harvester based on a simple portal frame structure is presented. The system is considered to be non-ideal system (NIS) due to interaction with the energy source, a DC motor with limited power supply and the system structure. The nonlinearities present in the piezoelectric material are considered in the piezoelectric coupling mathematical model. The system is a bi-stable Duffing oscillator presenting a chaotic behavior. Analyzing the average power variation, and bifurcation diagrams, the value of the control variable that optimizes power or average value that stabilizes the chaotic system in the periodic orbit is determined. The control sensitivity is determined to parametric errors in the damping and stiffness parameters of the portal frame. The proposed passive control technique uses a simple pendulum to tuned to the vibration of the structure to improve the energy harvesting. The results show that with the implementation of the control strategy it is possible to eliminate the need for active or semi active control, usually more complex. The control also provides a way to regulate the energy captured to a desired operating frequency. © 2013 EDP Sciences and Springer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To assess the intraocular pressure (IOP)-lowering effect of travoprost 0.004%/timolol 0.5% fixed-dose combination (TRAV/TIM-FC) in patients not achieving the target IOP of ≤18 mmHg while on timolol 0.5% (TIM) monotherapy. A multicenter, prospective, open-label study (NCT01336569) was conducted in patients with open-angle glaucoma or ocular hypertension. Eligible patients were receiving TIM monotherapy with a screening/baseline IOP of 19-35 mmHg in ≥1 eye. TIM was discontinued on the baseline visit day (no washout period) and TRAV/TIM-FC was initiated and administered once daily at 8 pm for 4-6 weeks. The primary efficacy variable was mean change in IOP from TIM-treated baseline to study end, measured by Goldmann applanation tonometry. Results were analyzed by analysis of variance and paired samples t-test (5% significance). A total of 49 patients were enrolled (mean age, 63 [range, 42-82] years; 55.1% White; 73.5% women), and 45 were included in the intent-to-treat (ITT) population. Mean duration of treatment with TRAV/TIM-FC was 31 days. Mean ± standard deviation IOP reduction from baseline (TIM) to the follow-up visit (TRAV/TIM-FC) was -5.0±3.6 mmHg. IOP decreased significantly (P<0.0001) from baseline (22.1±2.6 mmHg) to study end (17.1±3.9 mmHg) in the ITT population, with a mean IOP reduction of 22.3%. Most patients (n=33/45; 73.3%) achieved IOP ≤18 mmHg. Two patients experienced a total of four adverse events (AEs), including a patient who reported one serious AE (enterorrhagia) that was considered unrelated to treatment, and a patient who reported one event each of drug-related redness, pruritus, and foreign body sensation. Most patients (n=47/49; 95.9%) reported no AEs. TRAV/TIM-FC lowered IOP in patients who were not at target IOP while receiving TIM monotherapy, with most patients achieving an IOP ≤18 mmHg with TRAV/TIM-FC. TRAV/TIM-FC was well tolerated in this population.